![]() | Non-Resettable Thermal Fuse/Protectorss (JPE-360)17 visitsItem: RY Series Thermal Cutoffs/Fuses/Pretectors/Links Rating Current and Voltage 5-10/15A250V Temp Scope: 70-360deg Celsius; Over 100 Varieties Can Be Chosen Certification: PSE CCC ISO9001 Having Applied for the National Patent( above 240deg Celsius) Product Advantages The technological performance of products is high and the products have wide temperature specifications, especially the high temperature ones that could satisfy the requirements of the special consumers. The exported products implement the international authentication standard of Japan PSE and the products for domestic sale implement authentication standard of China CCC. The quality control of company are all inspected strictly from the purchasing products to all of the production procedure and the finished products leaving the plant. Japan Powerful company pursues the best service for the consumers. Whatever quantity customers order every time, all product logos are printed the one-shot batch number. If necessary, mark "**Special Provision" for your company. |
![]() | Fuse17 visitsWe supply series fuse box, fuse base, and fuse link. |
![]() | Breaker (VTD3142P)20 visitsMain technical data Rated voltage 12kV Rated current 630A Rated frequency 50Hz Rated short-time power frequency withstand voltage 42kV Rated lightring impulse withstand voltage 75kV Rated short-circuit breaking current 12.5/16/20KA Rated short-circuit making current 31.5/40/50kA Rated operations of short-circuit breaking current interruption 30 times Rated single capacitor bank breaking current 400A Rated short-time withstand current 12.5/16/20KA Rated peak withstand current 31.5/40/50kA Rated duration of short-circuit 4s Mechanical life 10000times Contact closing force due to bellows and atmosphere 70± 40N Counterforce at rated contact stroke 120± 50N Circuit resistance at rated contact force ≤ 25μ Ω Shelf life 20years Contact erosion limit 3mm Weight of moving parts ≤ 1kg Mechanical data required for matched vacuum interrupter Rated contact stroke 9± 1mm Average opening speed 1.0± 0.25m/s Average closing speed 0.65± 0.15m/s Added contact force 900/1300/1600± 100N Contact bouncing duration at closing operation ≤ 2ms Contact bouncing bank amplitude of opening operation ≤ 2mm Three-pole simultaneity ≤ 1ms |
![]() | 33kV Indoor Hi-Voltage Vacuum Circuit Breaker (ZN85-40.5 Series)16 visitsZN85-40.5/T type indoor high voltage indoor vacuum circuit-breaker is used for switchgear KYN61-40.5(Z), it is most new type of power supply and distribution equipment. This product is accordance with GB1984-2003 stand. This series include: Vacuum circuit breaker truck, isolation truck and fuse truck. Structural characteristics: 1. This vacuum circuit breaker adopts compound insulation; It can meet air distance and creepage under normal run condition, and it effectively reduces the dimension of VCB, the overall arrangement is reasonable and simple, with aesthetic appearance. 2. The operating mechanism is especially newly designed for this VCB; The outlet curve has good adaptation with requirements of vacuum interrupters. It has high reliable with characteristics of long life and easy maintenance and free-maintenance for operating mechanism. 3. This truck adopts screw rod nut push-in mechanism which can realize easy pushing-in or pushing-out of panel; Compulsive mechanical interlock way is adopted; Meet the Five Preventions function; Suitable for varies site and the working sites which have rigorous run condition. |
![]() | Mini Circuit Breaker DZ47 series17 visitsDZ47 series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system. The product is novel in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly and it's installation uses with guide, it's case and items are adopted with high fire-retardant and shockproof plastics. The product, with long life, is mainly used in AC 50Hz/60Hz single-pole 240V or two, three, four-pole 415V circuit for overload and short-circuit protection as well as for unfrequented on-and-off switching electric equipment and lighting circuit in normal case. |
C C Temperature Fuse19 visitsCc Temperature Fuse(over heat fusible) is a heat protective device that can not restoration. It is applicated in home appliances and the over-heat protective of the industrial equipments, when the temperature around rise to unusual, cc temperature fuse will affect the outer-temperature and then cut off the circuit. Its sealed construction can insure stabilization and credibility of the fusible system, and wonot affected by the scurviness environment such as outer-humidity. The temperature of the equipment rises unusual, the temperature fuse(overheat type) affectd by the environment tempreture, when the temperature reached the melting point Of the fusion, it will melt. And melted alloy shrink to a ball quickly and then cut off The current. |
|
Residual Current Operated Circuit Breaker16 visits1.1 Certificates:CE, PCT; 1.2 Electric ratings:Up to 32A, 230/400V, AC50/60Hz; 1.3 Tripping characteristics:C, D; 1.5Rated insulation voltage Ui:500 V; 1.6 Rated impulse withstand voltage Uimp:6000 V; 1.7 Life (operations): A.Electric life:2000, COS?=0.85~0.9 B.Mechanical life:2000 1.8 Standard:IEC/EN 61009-1 |
|
![]() | Mould Case Circuit Breaker (MCCB)19 visitsIt is used in rated current (In): 63A-800A, Rated operational voltage (Un): up to 660V(690V), AC50HZ (60HZ), Insulation voltage 800V, Standard: IEC60947, GB14048. BLM2 series Mould Case Circuit Breakers are designed to product the cable, leading wires, bus bars, electric motors, transformers and power consumption Features: 1) Attractive design 2) High breaking capacity 3) Light weight plastic frame and parts 4) Reliable performance 5) Flame-resistant, shock-resistant 6) Long service life 7) Overload and short circuit protection within AC 50/60Hz circuits 8) Also used as an infrequent circuit switchover under normal conditions |
![]() | Air Circuit Breaker up to 690V 6300A (Earth Leakage Circuit Breaker)16 visitsEARTH LEAKAGE CIRCUIT BREAKER 1. Poles 2, 3, 4 2. Rated operating voltage up to 400V 3. Frequency 50Hz or 60Hz 4. Rated current: 3A up 800A 5. Rated desidual-break current: 30mA up 1000mA |
![]() | Minitype Breaker - DZ47-63, DZ47-100, NC_100H20 visitsThis factory holds advanced production equipment, precise detecting instruments, first-rate technologies, scientific managing methods, a strict system of staff and a lot of skilled and hard-working technicians and administrators so as to make sure of each product on the production line to be reliable and has paid much attention to the investment of science and talents by means of continual importing new equipment, new know-how, new talents and developing new products so as to, by doing its best, provide users with the brand-new, qualified and inexpensive products. |